Published on 2017-11-13
Finetek improves the SD Optical Level Switch
The optical liquid level switch uses the principle of total reflection in a prism. Reflection or
penetration, is the basis of the level alarm output. When the sensor is surrounded by air,
the angle of incidence is greater than the critical angle and thus total reflection occurs.
Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is
surrounded by liquid, due to the refractive index of the liquid and the sensor tip material,
almost all light will penetrate the front of the sensor. Using this principle, the optical liquid
level switch design is based on light. The receiver can detect and determine a light
reflected or penetrated state, and determines the circuit output.