Position control for doors / casings on hazardous machinery
Manages person entry in hazard zones using an electrical locking key
Contactless encoded electronic sensor with relay
Category 3 total safety management without an external controller
Electrical locking key with position contact
Warranty: 3 years
Technical description
- Level of performance without an external controller: PL = d.
- Level of performance with AWAX controller: up to PL = e.
- Safety category without an external controller: 3.
- Safety Integrity Level: SIL 2.
- Cycle before dangerous failure: B10d = 2,000,000 at 2A.
- Max. activation distance: 10 mm, 2 mm hysteresis.
- Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts).
- Detection encoding: mono-code inviolable.
- Note: two-color LED indicates the key locking position; white LED indicates code recognition.
- Attachment: 4 tamper-proof M4 screws (optional ref: BH4).
- Mounting position: 2 (double wall brackets).
- Material: Polycarbonate.
- Electrical connection: M12 metal base.
- Water resistance: IP 65.
- Temperature: -15°C to +60°C.
- Marking: screen printed + serial no. for traceability.
Example of application
- Key free = sensor disabled. AUX2 output sends voltage (e.g. Unlock command). The operator takes the key and enters the zone.
- Key trapped = sensor activated. AUX2 output cuts the voltage (e.g. Lock command). The operator cannot enter; otherwise the sensor will be triggered, cutting off power to the machine.
Integrated auto-control
This product range integrates an auto-control device and dry contacts for use without an external control box (Pl d/SIL 2). Shock resistance: 10G.

MODELS
PRODUCT MODELS
Reference | Wiring | Material | Outputs | Category |
AMX5/CK |
50cm + M12 connector |
Plastic |
2NO+1NC |
CAT.3 + CAT4 on AWAX |